Acoustic
Menu

Acoustic

Key issues:

• Prevent condensation;
Minimize heat gain and boil off rate;
• Energy saving;
• Protect personnel;
• Acoustic insulation.

 Closed Cells Flexible Elastomeric Foam 
             First mechanical decoupling layer.
             K-FLEX SOLAR HT

   Open Cells Flexible Elastomeric Foam
             Absorption and dissipation layer.
             K-FLEX K-FONIK OPEN CELL

 High Density Elastomeric Material
             Mass barrier sound insulation layer.
             K-FLEX K-FONIK GK/GV

 Closed Cells Flexible Elastomeric Foam
             Second mechanical decoupling layer.
             K-FLEX ST            
             K-FLEX LS (USA Only)
             K-FLEX SOLAR HT

 Polymeric Outer Layer Jacketing
             UV and weather protective jacketing with joints sealed with K-FLEX sealant.
             K-FLEX IN CLAD Jacketing

K-FLEX acoustic insulation solutions are designed for noise reduction in industrial application e.g. piping, industrial processes etc.
A complete multilayer system based on both closed cells and open cells FEF materials provides acoustic insulation according to ISO 15665:2003 Class A, B, C; Shell DEP specification n°31 Class D; NORSOK STD R-004: Class 6, 7, 8; ASTM E1222.
Different materials with different proprieties feature different performance in the system. Each layer has been designed for a specific purpose.
Closed cells FEF layer (K-FLEX ST or K-FLEX HT) works as a mechanical decoupling.
Open cells FEF layer (K-FLEX K-FONIK OPEN CELL) provides sound absorption and dissipation.
High density material (K-FLEX K-FONIK GK/GV) works as mass barrier and sound insulator.
External jacketing layer (K-FLEX IN CLAD) provides mechanical and weather protection.
ISO 15665:2003 defines the acoustic performance of three classes (classes A, B and C) of pipe insulation. It is applicable to the acoustic insulation of cylindrical steel pipes and to their piping components. It is valid for pipes up to 1 m in diameter and a minimum wall thickness of 4,2 mm for diameters below 300 mm, and 6,3 mm for diameters from 300 mm and above.
ISO 15665:2003 covers both design and installation aspects of acoustic insulation and provides guidance to assist noise control engineers in determining the required class and extent of insulation needed for a particular application.

MINIMUM INSERTION LOSS REQUIRED FOR EACH CLASS, ISO 15665:2003

 

CLASS

 

Nominal Pipe Diameter
D mm

Octave band centre frequency, Hz
125 250 500 1000 2000 4000 8000 
lower limit upper limit Minimum insertion loss, dB
A1    < 300 -4 -4 2 9 16 22  29
A2

≥ 300

< 650 -4 -4 2 9 16 22 29
A3 ≥ 650 < 1000 -4 2 7 13 19 24 30
B1   < 300 -9 -3 3 11 19 27 35
B2 ≥ 300 < 650 -9 -3 6 15 24 33 42
B3 ≥ 650 < 1000 -7 2 11 20 29 36 42
C1   < 300 -5 -1 11 23 34 38 42
C2  ≥ 300 < 650 -7 4 14 24 34 38 42
C3 ≥ 650 < 1000 1 9 17 26 34 38 42

K-FLEX ACOUSTICAL CONFIGURATIONS FOR ISO 15665 CLASSES

 K-FLEX K-FONIK INDUSTRIAL “A2”
 

Test Result Class A2
nom. pipe-Ø: ≥ 300mm to < 650 mm

Weight:

Octave band centre frequency, Hz

125 250 500 1000 2000 4000 8000
Minimum insertion loss, dB

1 Layer K-FLEX SOLAR HT, 1 Layer K-FLEX IN CLAD

5Kg/m2

1,5 1 8 12,5 18,5 29,5  37,5 

K-FLEX K-FONIK INDUSTRIAL “B2”

 

Test Result Class B2
nom. pipe-Ø: ≥ 300mm to < 650 mm

Weight:

Octave band centre frequency, Hz

125 250 500 1000 2000 4000 8000
Minimum insertion loss, dB

1 Layer K-FLEX SOLAR HT, 1 Layer K-FLEX K-FONIK 240,
1 Layer K-FLEX IN CLAD

 12Kg/m2 -0,5 2,5 14,5 22,0 32,0 43,5 47,5

K-FLEX K-FONIK INDUSTRIAL “C2”

 

Test Result Class C2
nom. pipe-Ø: ≥ 300mm to < 650 mm

Weight:

Octave band centre frequency, Hz

125 250 500 1000 2000 4000 8000
Minimum insertion loss, dB

1 Layer K-FLEX SOLAR HT, 1 Layer K-FLEX K-FONIK 240
2 Layers K-FLEX K-FONIK GK, 1 Layer K-FLEX IN CLAD

 25Kg/m2 -1,5 4,5 17,5 30 45 51 51,5

K-FLEX K-FONIK INDUSTRIAL “C2”

 

Test Result Class C2
nom. pipe-Ø: ≥ 300mm to < 650 mm

Weight:

Octave band centre frequency, Hz

125 250 500 1000 2000 4000 8000
Minimum insertion loss, dB

1 Layer K-FLEX SOLAR HT, 1 Layer K-FLEX K-FONIK 240,
2 Layers K-FLEX K-FONIK GK, 1 Layer K-FLEX SOLAR HT,
1 Layer K-FLEX IN CLAD

 27Kg/m2 -0,5 4,5 16 24 38,5 51,5 51,5

K-FLEX K-FONIK INDUSTRIAL “D2”

 

Test Result Class D2
nom. pipe-Ø: ≥ 300mm to < 650 mm

Weight:

Octave band centre frequency, Hz

125 250 500 1000 2000 4000 8000
Minimum insertion loss, dB

1 Layer K-FLEX SOLAR HT, 2 Layers K-FLEX K-FONIK 240,
1 Layer K-FLEX K-FONIK GK, 1 Layer K-FLEX ST,
1 Layer K-FLEX IN CLAD (2mm)

29Kg/m2 0 8,5 24,5 38,5 52 55 49

1 Layer K-FLEX SOLAR HT, 2 Layers K-FLEX K-FONIK 240,
1 Layer K-FLEX K-FONIK GK, 1 Layer K-FLEX ST,
1 Layer K-FLEX IN CLAD (1mm)

28Kg/m2  -1 6,5 20,5 37 52  55,5  49 

1 Layer K-FLEX SOLAR HT, 2 Layers K-FLEX K-FONIK 240,
1 Layer K-FLEX K-FONIK GK, 1 Layer K-FLEX SOLAR HT,
1 Layer K-FLEX IN CLAD (2mm) 

30Kg/m2 -1  8,5  20  36  51  56  50,5 
Last modified onFriday, 16 January 2015 08:09